Amsphere A3 – Protein A Resin: Anoptimized Media to Minimize the Impact of Elution Buffer Selection

Protein A chromatography is widely used as the affinity capture step of both mAbs and Fc-fusion proteins because of its high degree of selectivity. Variations in elution behavior of the protein A capture step require more process development work and could have an impact on the polishing step in the downstream process. Thus, minimizing the variation in elution pH between different molecules for example, makes it easier to platform the capture process.
Amsphere A3 was designed so that differences in washing and elution buffers (type, conductivity and pH) have minor effects on the characteristics of the elution pool (pH, impurity levels, yield, etc). In this application note, the impact of the elution buffer counter-ion, pH and molarity were evaluated on the key purification performance parameters (HCP removal, yield, elution volume and pH of the elution pool) of Amsphere A3. In total, 5 different mAbs were used for the study.

TABLE 1: mAbs USED FOR THE STUDY

Study Methods and Materials
Agarose was tested in comparison with Amsphere A3. Five mAb samples (Table 1), expressed in Chinese Hamster Ovary (CHO) cells and clarified by centrifugation, were tested. The impact of the antibody loading quantity on elution pH was investigated using Trastuzumab and 3 loadings (10, 20 and 30 mg) with the experimental conditions displayed in Figure 1. The on-line pH measured at the UV peak maximum during product elution (UV 300 nm) was reported. The impact of the antibody loading on the UV300/pH relation was investigated.
The conditions for the impact of various elution buffers (type, molarity, pH) on purification performance of Amsphere A3 are given in association with the results below.

Results

1. EVALUATING THE IMPACT OF ANTIBODY LOADING QUANTITY ON ELUTION pH

2. EVALUATION OF THE VARIABILITY IN ELUTION pH

3. IMPACT OF VARIOUS ELUTION BUFFERS (TYPE, MOLARITY, pH) ON PURIFICATION PERFORMANCE OF AMSPHERE A3

Overall Conclusion
For Amsphere A3 the impact of elution buffer counter-ion, pH and molarity on key purification performance parameters was investigated. The HCP clearance was good for all mAbs tested. There was also no dependence of buffer counter-ion, pH and/or molarity on the HCP clearance.
Amsphere A3 is a platform-ready resin with outstanding performance. This allows use of preferred elution conditions while still obtaining good performance. Furthermore, there is almost no need to tailor or optimize buffers, allowing fast process development.

AmsphereTM is a global trademark of JSR Corporation©2016-2017 JSR Corporation – All rights reserved.
For more information visit www.jsrlifesciences.com



Subscribe to our FREE newsletter and WEBINAR UPDATES

We will not sell or give your information to a third party. See our Privacy Policy